Tektelic KONA 16 Macro
Prerequisite
Enable Root Access
Log into the box with the username "admin"
Run this command to enable root access (BSP 5.1.x+)
sudo opkg remove disable-root-login
Once this package is removed you can log into the box with the username "root" and the default Tektelic password
Remove the following opkg's
opkg remove kona-pkt-forwarder
opkg remove tektelic-mqtt-bridge
Reboot the system
In order for the mqtt-bridge process to be properly terminated you will need to reboot the system.
tektelic_reset
Supported Senet Packet Forwarder Versions |
---|
02_22_XX - Release Notes |
02_20_XX - Release Notes |
Senet Packet Forwarder for Developers
Registration
If you have not done so already you will need to register your gateway through your Developer or RAN Provider account.
Note
The serial number for this device is the 8 digit Product Type (starting with a "T") an underscore "_" followed by the 9 digit serial number which can be found on bottom of the Base Station.
Installation
Copy and paste the following command into the Tektelic KONA 16 Macro root SSH console.
BSP Version | Command | |
---|---|---|
BSP: 4.3.X |
|
|
BSP: 5.1.X |
|
Run the command. The installation is automatic and will prompt you once it has completed.
reboot
Once registration and Base Station software installation are complete the Base Station will be displayed in the Senet Portal Dashboard with the current registration status (this may require a refresh of the browser).
Senet Packet Forwarder for RAN Providers
Note
Before installing verify you have properly configured your network settings on the gateway. The installation process will apply security measures which include modifications to the firewall as well as the password; the installer may also configure the system and install new packages. Access to the gateway over the local network through such protocols as SSH and telnet will no longer be available upon completion of the installer.
Registration
If you have not done so already you will need to register your gateway through your Developer or RAN Provider account.
Note
The serial number for this device is the 8 digit Product Type (starting with a "T") an underscore "_" followed by the 9 digit serial number which can be found on bottom of the Base Station.
Installation
Copy and paste the following command into the Tektelic KONA 16 Macro root SSH console .
BSP Version | Command | |
---|---|---|
BSP: 4.3.X |
|
|
BSP: 5.1.X |
|
Run the command. The installation is automatic and will prompt you once it has completed.
reboot
Once registration and Base Station software installation are complete the Base Station will be displayed in the Senet Portal Dashboard with the current registration status (this may require a refresh of the browser).